A deck in Seattle's Neighborhood Residential zone needs 10–15 ft from the front lot line, depending on the homes on the lot, 0 from the rear lot line, depending on the alley, and 5 ft on average (at least 3 ft) from the side lot line. It can be up to 32 ft tall. All buildings together can cover up to 50% of the lot.
Enter an address and Feasy draws these rules on your actual lot.
A setback is a distance a building has to stay back from a lot line. Here is what the code calls it, and how far a deck has to stay back from each line.
Front
At least 15 ft. (1 or 2 homes) At least 10 ft. (3 or more homes)
What the code says: Seattle Municipal Code 23.44.090.A
Rear
No rear setback is required. (No alley) No rear setback is required. (Alley behind the lot)
What the code says: Seattle Municipal Code 23.44.090.H.8
Side
5 ft on average. At least 3 ft.
What the code says: Seattle Municipal Code 23.44.090.A
Side street
5 ft on average. At least 3 ft.
What the code says: Seattle Municipal Code 23.44.090.A
A. Required setbacks for the NR zones are shown in Table A for 23.44.090.
Table A for 23.44.090Required setbacks in Neighborhood Residential zones1
Front2 Lots with one or two dwelling units 15 feet Lots with three or more dwelling units 10 feet Rear3 Lots with one or two principal dwelling units not abutting an alley 15 feet Lots with three or more principal dwelling units not abutting an alley 10 feet Lots under 5,000 square feet within frequent transit service areas 5 feet If the rear setback abuts an alley, no rear setback is required Side Lots under 5,000 square feet within frequent transit service areas 3 feet All other lots 5 feet average, 3 feet minimum
- 1 Required setbacks for lots with nonresidential structures are the same as the required setbacks for lots with three or more dwelling units.
- 2 For lots abutting landmark public right-of-way on Queen Anne Boulevard, front setbacks shall be 20 feet or the average of the front setbacks of the structures on abutting lots, whichever is less, except that if the natural gradient or slope (as measured from the front line of the lot for a distance of 60 feet or the full depth of the lot, whichever is less) is in excess of 35 percent, the required front setback depth shall be the lesser of: 20 feet less one foot for each one percent of gradient or slope in excess of 35 percent; or the average of the front setbacks on the abutting lots.
- 3 The rear setback for accessory dwelling units is 5 feet, except that, if the rear setback abuts an alley, no rear setback is required.
H. Other unenclosed structures allowed in setbacks
8. Unenclosed structures are allowed in the rear setback provided that the structure is:
A. For purposes of setback and separation standards, measurement shall be taken to the outside of building foundations and exterior walls rather than to exterior finishing provided that exterior finishes extend no more than 8 inches into a required setback.
Height
Up to 32 ft. (1 or 2 homes) Up to 32 ft. Up to 42 ft when the front setback is at least 20 ft. (3 or more homes)
A. Maximum height established
1. Subject to the exceptions allowed in this Section 23.44.070, the height limit is 32 feet for any structure not listed in subsections 23.44.070.A.2 or 23.44.070.A.3;
B. Standards for pitched roofs
1. The ridge of a pitched roof that is not a shed or butterfly roof may extend up to 5 feet above the maximum height limit, as determined under subsection 23.44.070.A. All parts of the roof above the height limit must be pitched at a rate of not less than 4:12 (see Exhibit A for 23.44.070).
B. Standards for pitched roofs
2. The high side(s) of a shed or butterfly roof may extend 3 feet above the maximum height limit, as determined under subsection 23.44.070.A, provided that the low side(s) of the shed or butterfly roof are no higher than the height limit (see Exhibit B for 23.44.070). The roof line of a shed or butterfly roof may be extended in order to accommodate eaves, provided that the highest point of the roof extension is no more than 4 feet above the height limit.
A. Maximum height established
2. The height limit is 42 for the following types of development:
a. Any development with three or more principal dwelling units and a front setback of at least 20 feet;
Structure coverage
Up to 50% of the lot: 2,000 sf on a 4,000 sf lot. This counts every structure on the lot together.
A. Except as otherwise provided in this Section 23.44.080, the maximum lot coverage allowed for structures is 50 percent.
Floor area (whole lot)
Up to 0.8 ratio. (1 or 2 homes) Up to 1.6 ratio. (3 or more homes)
B. Floor area ratio (FAR) limits. The FAR limit in Neighborhood Residential zones for lots with residential uses is as shown in Table A for 23.44.050, except that structures on lots with less than 5,000 square feet of lot area can include up to 2,500 square feet of total chargeable floor area or the amount of total chargeable floor area allowed by the FAR limit shown in Table A for 23.44.050, whichever is greater. The FAR limit in Neighborhood Residential zones for lots without residential uses is 1.2. The applicable FAR limit applies to the total chargeable floor area of all structures on the lot.
Table A for 23.44.050 Floor area ratio (FAR) in NR zones
Density (dwelling units per lot size) FAR Less dense than 1 unit/4,000 square feet 0.6 1 unit/4,000 square feet to 1 unit/2,201 square feet 0.8, or 1.0 if the development meets the standards of subsection 23.44.050.D 1 unit/2,200 square feet to 1 unit/1,601 square feet 1.0, or 1.2 if the development meets the standards of subsection 23.44.050.D 1 unit/1,600 square feet or denser 1.6 for attached and detached dwelling units, except that it is: • 1.8 for development on lots located within a frequent transit service area that consist entirely of attached or detached dwelling units in structures that are less than three stories and that are arranged on up to three sides of a common, ground-level amenity area equal to at least 20 percent of the lot area that includes usable, contiguous community green space and trees; • 1.8 for stacked dwelling units that do not meet the standards of subsection 23.44.050.D or 23.44.050.E; or • 2.0 for stacked dwelling units that meet either the standards of subsection 23.44.050.D or 23.44.050.E.
A. General requirements
4. Detailed requirements for street improvements are in the Right-of-Way Improvements Manual.
A. The street in the block where it abuts the lot is wholly undeveloped, is unpaved, or is developed with a roadway less than twenty (20) feet in width; and
B. The street provides either no access or only secondary access to those lots to which it abuts; and
C. The development proposed for the lot does not require improvement of the street and no plans to develop the street are on file with the City; and
D. Existing streetscapes and development patterns are not disrupted. (Ord. 115326 § 3, 1990.)
C. Other setback requirements. Additional structure setbacks may be required in order to meet the provisions of Chapter 23.53.
A. Required setbacks for the NR zones are shown in Table A for 23.44.090.
Table A for 23.44.090Required setbacks in Neighborhood Residential zones1
Front2 Lots with one or two dwelling units 15 feet Lots with three or more dwelling units 10 feet Rear3 Lots with one or two principal dwelling units not abutting an alley 15 feet Lots with three or more principal dwelling units not abutting an alley 10 feet Lots under 5,000 square feet within frequent transit service areas 5 feet If the rear setback abuts an alley, no rear setback is required Side Lots under 5,000 square feet within frequent transit service areas 3 feet All other lots 5 feet average, 3 feet minimum
- 1 Required setbacks for lots with nonresidential structures are the same as the required setbacks for lots with three or more dwelling units.
- 2 For lots abutting landmark public right-of-way on Queen Anne Boulevard, front setbacks shall be 20 feet or the average of the front setbacks of the structures on abutting lots, whichever is less, except that if the natural gradient or slope (as measured from the front line of the lot for a distance of 60 feet or the full depth of the lot, whichever is less) is in excess of 35 percent, the required front setback depth shall be the lesser of: 20 feet less one foot for each one percent of gradient or slope in excess of 35 percent; or the average of the front setbacks on the abutting lots.
- 3 The rear setback for accessory dwelling units is 5 feet, except that, if the rear setback abuts an alley, no rear setback is required.